Vsh1230 clean agent fire suppression system novec 1230. Safety data sheet file no incoming sds novec 1230 00 sds. In a typical total flooding system, the fluid is stored as a liquid in cylinders pressurized with nitrogen. The atmospheric lifetime of 3m novec 1230 fluid is estimated to be in the range of 35 days and with a global warming potential of 1, it is considered that the 3m novec 1230 fluid has no measurable impact on climate change. Novec 1230 novec 1230 is a registered trade mark of the 3m. Generally, a system using novec 1230 fluid will extinguish a fire even before it reaches the flame stage. The novec 1230 fire suppression system developed by 3m is a clean agent system. Novec 1230 fluid extinguishes a fire before it starts by rapidly removing heat. Novec 1230 fluid is a clear, colorless and low odor liquid perfectly suited to protect high value assets in areas that may be normally.
It does not leave any residue behind, and there is no need for costly cleanup operations. Gielle is certified manufacturer of fire protection systems using novec 1230 fluid, a new development. Novec 1230 fluid has a global warming potential gwp of less than one while hfcs typically have a gwp of more than 3000. Novec 1230, fk5112, c 6 f 12 o is a fluorinated ketone with the systematic name 1,1,1,2,2,4,5,5,5nonafluoro4trifluoromethyl3pentanone and the structural formula cf 3 cf 2 cocfcf 3 2, a fully fluorinated analog of ethyl isopropyl ketone, and is commercially available from 3m. Design, supply and install a complete clean agent total flooding fire suppression system using novec 1230 fire protection fluid hereafter referred to as system which meets all the performance criteria described herein. Contact carl busian at 18009191288 ex 201 to discuss your novec fire suppression system needs. Clean agent suppression systems using novec 1230 fluid. Fast extinguishment helps keep fires small, giving them less chance to spread. Gielle is certified manufacturer of fire protection systems using novec 1230 fluid, a new development with some advantages over current technologies. Novec 1230 is truly a real breakthrough in clean agent technology, a liquid at room temperature, it looks, feels and acts like water, allowing flexibility in recharge procedures. Accidental release measures personal precautions, protective equipment and emergency procedures wear appropriate protective clothing. The novec 1230 system uses a fluid fluoroketone to extinguish a fire. Upon discharge of the preengineered novec tm 1230 fire suppression system, the extinguishing agent floods the compartment with an electrically nonconductive, noncorrosive vapor that stops the combustion process by physical means. It is used as gaseous fire suppression agent in scenarios where waterbased fire suppression for example.
Discharge of a fire protection system using novec 1230 fluid in place of an hfc extinguishing agent results in significantly reduced greenhouse gas emissions. The mindful science behind novec 1230 fluid becomes even more evident when you compare it with the alternatives. All data were negative in a 2 hour rat inhalation study nervous system. With 50 years of experience, gielle is the specialist in fire safety. Fire suppression 3m novec 1230 3m united arab emirates. Novec 1230 fire suppression system for fire protection. Although the design of a new novec 1230 system will be similar to a fm200 system an upgrade will not and particular care.
Novec 1230 systems tc approved description kidde engineered fire suppression system 900 lb. Automatic detection sensors trigger release when the fire is at the incipient stage, extinguishing it in mere seconds. The novec 1230 extinguishant is then deployed via this diffuser directly into the heart of the fire. The firetrace system requires no external power source or separate detectors and owing to its simple design ensures that all of the extinguishant is always deployed in the fire area. With the only novec 1230 system approved for use with selector valves, minimax can deliver cost savings and system flexibility for large area protection. Whether you are looking to replace a halon fire protection system, find an fm200 replacement, install an environmentally friendly system or increase the margin of safety for your workers, novec 1230 fluid has so much to offer. The width of the bar refers to the possible complexity of the pipe run indication only. Novec 1230 fluid knocks down fires in less than half the time of co 2 agents. The system uses novec tm 1230 manufactured by 3m tm hereinafter referred to as extinguishing agent as its extinguishing agent.
It is effective on a wide range of class a, b and electrical. Design, supply and install a complete clean agent total flooding fire suppression system using novec 1230 fire protection fluid hereafter referred to as system which meets all the performance criteria described herein clean agent fire suppression fluid a. The sapphire clean agent system quickly suppresses fires and protects. This results in the best coverage, highest nozzle, smallest diameter pipe and longest pipe runs. What you need is a kidde engineered fire suppression system, which uses the latest. Protect valuable equipment, people and assets with a clean agent fire suppression system using 3m novec 1230 fire protection fluid. Q what operations and valued assets is novec 1230 fluid used to protect. Download the 3m novec 1230 fire protection fluid brochure pdf, 1. Copy and paste the following text into your specification or download the full specification example summary of work a. Ecsfire suppression system with novec1230 fire protection fluid august 2014 page 5 of 7 2. Novec 1230 fluid revolutionized the fire protection market 15 years ago. This system reacts quickly to a fire, leaves behind no residue, and is electrically nonconductive. Novec 1230 fluid has the highest margin of safety for human occupancy among clean agents, including inert gas.
Imperial novec1230 fire suppression system simulation. Novec 1230 fire system the search for halon 1 replacements has been ongoing for over 10 years and each alternative brings with it a unique set of properties. Novec 1230 fluid is a fluoroketone, while chemical clean agents like fm200 are hfcs hfc227ea. Safety data sheet 3m novec 1230 fire extinguishing agent. The kd1230 system consists of 3mtm novectm 1230 fire protection fluid stored in cylinders. Sinorix 1230 clean agent extinguishing systems siemens. Novec is calculated to discharge within 10 seconds, and is normally calculated at a 4. Vsh1230 fire extinguishing system with 3m novec 1230 fire. Novec 1230 upon discharge of the preengineered novec tm 1230 fire suppression system, the extinguishing agent floods the compartment with an electrically nonconductive, noncorrosive vapor that stops the combustion process by physical means.
Novec 1230 fluid is formed from the elements carbon, fluorine and oxygen cf3cf2cocfcf32 dodecafluoro2methylpentan3one. Distribution piping, and fittings, shall be installed in accordance with nfpa 2001, approved piping standards and the engineered fire suppression system manufacturers requirements. Sinorix 1230 clean agent extinguishing systems siemens global. Today, with more than 50,000 system installations in over 90 countries, and the approvals to back up our promises, we continue to move the industry forward with the purpose of delivering a solution that is designed to work now and for years to come.
Vsh1230 clean agent fire suppression system novec 1230 extinguishing agent design manual. It does not cover fire extinguishing systems that use carbon dioxide or water as the primary extinguishing media, which are addressed by other nfpa documents. Automated extinguishing system based on clean agent novec 1230 fluid sinorix 1230 is the latest generation of our chemical extinguishing systems, offering a range of unique features and benefits. This extinguishing agent is suitable for suppressing class a and class b fires and stored in the systems extinguishing agent containers. This standard contains minimum requirements for total flooding and local application clean agent fire extinguishing systems. It does this by reaching extinguishing concentrations in ten seconds or less. A upon activation from an automatic fire extinguishing system, novec 1230. Novec tm 1230 removes heat energy from the fire to the extent that the combustion reaction cannot sustain itself. Highly effective and safe for people, the environment, and sensitive. Ecsfire suppression system with novec 1230 fire protection fluid august 2014 page 5 of 7 2.
To create the pressure necessary for the agent to be released, the. A novec 1230 fluid is designed to help protect continuity of operations because, unlike water, it does not damage. System depictions, calculations, graphs or reports pro vided by the manufacturer or private labeler of the prod ucts, described in this manual, are for illustrative pur. Feb 16, 2016 the janus fire systems sv 500 series clean agent fire suppression system utilizes 3m novec 1230 fire protection fluid as the extinguishing medium. It is an excellent solution for the protection of highvalue assets, business processes and people. The primary extinguishing mechanism of novec 1230 fluid is heat absorption, with a secondary chemical contribution from the. Novec 1230 can be used in both totalpartiallocalized flooding systems, and directional spray type applications. Today, with more than 50,000 system installations in over 90 countries, and the approvals to back up our promises, we continue to move the industry forward with the purpose of delivering a solution that is. This publication describes the operation, installation and maintenance of the system. It also has a higher safety margin than other clean agents, making it extremely. Inert gas fire suppression system simulation duration. Our exclusive 725 psi system allows longer pipe runs, smaller pipe sizes, remote tank location, and multizone protection from a single cylinder bank.
Contact an aft specialist for help with novec 1230, including the associated detection and control equipment. Certified manufacturer of fire suppression system using novec 1230. Ecs fire suppression system with novec part 1 general. This extinguishing agent is suitable for suppressing class a and class b fires and stored in the system s extinguishing agent containers. This manual is intended to clearly and accurately reflect the kidde engineered fire suppression system designed for use with 3m novec 1230 fire protection fluid. In conclusion novec 1230 prior to 1st january 2018 was the most expensive of the agents we use for fire suppression system, but with the massive increase in price of fm200 due to an eu reduction of 36% has meant novec 1230 is now the only real alternative to inert gas.
The cylinders are painted red and are equipped with a 3inch pressure differential valve, pressure gauge. Our mx 1230 fire extinguishing system uses 3m novec 1230 fire protection fluid, which will not damage electronics and leaves no residue behind. Whether you need portable fire equipment, service and maintenance, or largescale fire suppression systems for mining, marine, industrial, commercial and retail use. Due to the dramatically lower gwp, greenhouse gas emissions from discharge of novec 1230 fluid are reduced by more than 99. Novec 1230 fluid is a clear, colorless and low odor liquid perfectly suited to protect high value assets in areas that may be normally occupied, in locations where cleanup of other agents is problematic, when storage space for a fire suppression agent is. Pdf, 510 kb, or visit the fire suppression novec 1230 webpage to learn more. System in this manual system refers to the extinguishing equipment and does not include any detection system which may initiate an agent release. The clear, colorless agent has zero ozone depletion potential, an atmospheric lifetime of just five days, and a global warming potential of 1. Safety data sheet 3m novec 1230 fire extinguishing. Novec 1230 fire suppression systems american fire technologies. In missioncritical fire suppression applications and tight spaces, a system using novec 1230 fluid can save substantial space over alternatives such as inert gas needing up to 5x fewer. Although the design of a new novec 1230 system will be similar to a fm200. It has been used as a fullimmersion fluid in a proof of concept data center cooling system by intel and sgi 1.
The sapphire system uses 3m novec 1230 fire protection fluid for total flooding applications. Having fewer cylinders also results in a system that is less complex, and typically less costly to install and maintain. Jan 11, 2019 the novec 1230 fire suppression system developed by 3m is a clean agent system. Clean agent system with fm200 or 3m novec 1230 utilizing the industry recognized fm200 and 3m novec 1230 suppression agents, janus has developed an affordable preengineered clean agent fire suppression system to protect areas with sensitive electrical equipment and valuable data. The primary extinguishing mechanism of novec 1230 fluid is heat absorption, with a secondary chemical contribution from the thermal decomposition of novec 1230 fluid in the flame. Engineered hydraulic flow program used to predict the two phase flow of novec 1230 through a pipe network.
942 1478 1365 309 114 1079 321 226 338 480 83 149 924 190 413 833 1529 301 1047 728 1326 1005 1346 677 1226 546 1401 950 1351 544 638 328